Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 POW-R-BLOK
TM
http://www.pwrx.com Single & Dual Diode Isolated Module
100 Amperes / Up to 1800 Volts
Revision Date: 08/31/2011
CD41__99C, CS41__99C
CC41__99C, CN41__99C
®
Outline Dimensions
Dimension
Inches
Millimeters
A
3.62
92
B
0.83
21
C
3.15
80
D
1.18
30
F
0.83
21
G
0.79
20
H
0.79
20
K
0.24
6.2
L
0.63
16
M
0.51
13
N
0.33
8.5
U
M5
M5
Note: Dimensions are for reference only.
Select the complete nine digit module
part number from the table below.
Example: CD411699C is a 1600Volt,
100 Ampere Dual Diode Isolated
POW-R-BLOK
TM
Module
Type
Voltage
Volts
(x100)
Current
Amperes
Version
CD41
CS41
CC41
CN41
08
12
14
16
18
99
(100 A)
C
CD41__99C, CS41_99C,
CC41__99C, CN41_99C
Single & Dual Diode Isolated
POW-R-BLOK
TM
Module
100 Amperes / Up to 1800 Volts
Description:
Powerex Single and Dual Diode
Modules are designed for use in
applications requiring rectification and
isolated packaging. The modules are
isolated for easy mounting with other
components on a common heatsink.
Features:
Electrically Isolated Heatsinking
Compression bonded construction
Low Thermal Impedance
for Improved Current Capability
RoHS Compliant
UL Recognized (E78240)
Benefits:
No Additional Insulation
Components Required
Easy Installation
No Clamping Components
Required
Reduce Engineering Time
Applications:
Power Supplies
Bridge Circuits
AC & DC Motor Drives
Battery Supplies
Large IGBT Circuit Front Ends
Lighting Control
Heat & Temperature Control
Welders
Page view 0
1 2 3 4

Summary of Contents

Page 1 - CC41__99C, CN41__99C

Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 POW-R-BLOKTM http://www.pwrx.com

Page 2

Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 POW-R-BLOKTM http://www.pwrx.com

Page 3

Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 POW-R-BLOKTM http://www.pwrx.com

Page 4

Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 POW-R-BLOKTM http://www.pwrx.com

Comments to this Manuals

No comments